HILDAGE Syringe Pump
Syringe pump for controlled drug delivery with all standard syringe sizes from 2 to 60 mL, ±2% flow accuracy, touch screen and keypad entry, and password-protected settings.
Volumetric infusion pump for fluids and medication, compatible with most standard IV sets, with an anti-bolus system and automatic stop on critical alarms.
Set the parameters with the dial, confirm with the push button and start therapy with the start button.
Adjustable air-in-line sensitivity, and detection of upstream occlusion.
Installs on the pump pole in one click, with no screws.
An external power supply reduces the risk of the power module overheating.
Download settings and upload therapy data over Wi-Fi.
1.5 kg; 132 × 95 × 165 mm (W × D × H); works over 6 hours on battery.
As published by the manufacturer. Confirm against the registered labelling before tender submission.
| Delivery | |
|---|---|
| Flow rate | 0.1–1800 mL/h, in 0.1 mL/h steps |
| Volume to be infused | 0.1–9999.9 mL, in 0.1 mL steps |
| Accuracy | ±5% |
| Purge / bolus rate | 1–1800 mL/h adjustable, ±20% |
| KVO rate | 3 mL/h at flow rates above 10 mL/h; 1 mL/h at 1–10 mL/h; equal to the flow rate below 1 mL/h |
| IV sets | Most standard IV sets, with user calibration |
| Safety | |
| Alarms | Air in line, occlusion, door open, infusion near end, VTBI complete, pause overtime, low battery, battery exhausted, malfunction, AC and DC off |
| Air-in-line sensitivity | Adjustable |
| Upstream occlusion | Detected |
| Occlusion pressure | High 100 ± 30 kPa; low 50 ± 20 kPa |
| Anti-bolus | A.B.S anti-bolus system |
| Critical alarms | Infusion stops automatically |
| Display and connectivity | |
| Display | 3.5" TFT-LCD |
| Operation | Keypad |
| USB | Firmware updates and calibration |
| Wi-Fi | Download settings and upload therapy data |
| Mounting | QuikMount: one-click pole installation, no screws |
| Power and physical | |
| Power adapter | Input 100–240 V AC, 50/60 Hz; output 15 V DC, 2 A |
| Battery | Lithium, 10.8 V nominal; over 6 hours of operation |
| Power consumption | Under 55 VA |
| Classification | Class II, Type CF, IPX2 |
| Dimensions | 132 × 95 × 165 mm (W × D × H) |
| Weight | 1.5 kg |
Source: hildmedical.com and the manufacturer's EGL IN Infusion Pump brochure, October 2026.
Available from CraftEdge. The manufacturer’s instructions for use specify the parts for each device.
Syringe pump for controlled drug delivery with all standard syringe sizes from 2 to 60 mL, ±2% flow accuracy, touch screen and keypad entry, and password-protected settings.
Bedside monitoring of ECG, SpO₂, NIBP, temperature and respiration, in 12-inch (EGL MP 121) and 15-inch (EGL MP 151) models.
Microprocessor-controlled ventilator for invasive and non-invasive ventilation of adult and paediatric patients, with twelve modes and high-flow oxygen therapy.